Remote Control Commands
R&S
®
SMA100B
606User Manual 1178.3834.02 ─ 05
[:SOURce]:LFOutput:VOLTage <Voltage>
Sets the voltage of the LF output.
Parameters:
<Voltage> float
Range: dynamic (see data sheet)
Increment: 0.001
*RST: 1
Example:
SOURce:LFOutput:VOLTage 1.5
[:SOURce<hw>]:LFOutput<ch>:SHAPe <Shape>
Selects the waveform shape of the LF signal.
Parameters:
<Shape> SINE | SQUare | TRIangle | TRAPeze
*RST: SINE
Example: See Example "Configuring the LF generator" on page 600.
Options: TRIangle|TRAPeze require R&S SMAB-K24
Manual operation: See "Shape" on page 99
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:DCYCle <DCycle>
Sets the duty cycle for the shape pulse.
Parameters:
<DCycle> float
Range: 1E-6 to 100
Increment: 1E-6
*RST: 50
Default unit: PCT
Example: See Example "Configuring the LF generator" on page 600.
Manual operation: See "Pulse Duty Cycle" on page 101
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:PERiod <Period>
Sets the period of the generated pulse. The period determines the repetition frequency
of the internal signal.
Parameters:
<Period> float
Range: 1E-6 to 100
Increment: 1E-8
*RST: 1E-3
Example: See Example "Configuring the LF generator" on page 600.
SOURce Subsystem