Analog Modulations
R&S
®
SMA100B
101User Manual 1178.3834.02 ─ 05
Period
Sets the repetition rate of the generated LF signal for triangle, trapezoid or pulse
shapes, see Shape.
The period of sine signals is calculated from the selected Frequency
Remote command:
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRAPeze:PERiod on page 607
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRIangle:PERiod on page 608
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:PERiod on page 606
Pulse Width
Sets the pulse duration of the generated pulse signal.
Remote command:
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:WIDTh on page 607
Pulse Duty Cycle
Sets the ratio between the pulse duration and the pulse period in percent.
Remote command:
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:DCYCle on page 606
Triangle Rise
Sets the time required for the triangle signal to change from low level to high level.
Remote command:
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRIangle:RISE on page 608
Trapezoid Rise / Fall
Sets the time required for the trapezoid signal to change from low level to high level,
and vice versa.
Remote command:
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRAPeze:RISE on page 608
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRAPeze:FALL on page 607
Trapezoid High
Sets how long the trapezoid signal is at high level.
Remote command:
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRAPeze:HIGH on page 607
Modulation Settings