Remote Control Commands
R&S
®
SMA100B
648User Manual 1178.3834.02 ─ 05
[:SOURce<hw>]:SWEep[:FREQuency]:DWELl <Dwell>
Sets the dwell time for a frequency sweep step.
Parameters:
float Range: 3E-3 (R&S SMAB-B709/-B710/-B710N), 5E-3
(R&S SMAB-B711/-B711N) to 100
Increment: 100E-6
*RST: 10E-3
Default unit: s
Note: The minimum dwell time varies, depending on the phase
noise options the instrument is equipped with (see the data
sheet for the specifications).
Example: See Example "Setup an RF frequency or power sweep"
on page 643.
Manual operation: See " Dwell Time " on page 174
[:SOURce<hw>]:SWEep[:FREQuency]:MODE <Mode>
Sets the cycle mode for the frequency sweep.
Parameters:
<Mode> AUTO | MANual | STEP
AUTO
Each trigger event triggers exactly one complete sweep.
MANual
The trigger system is not active. You can trigger every step indi-
vidually by input of the frequencies with the command [:
SOURce<hw>]:FREQuency:MANual.
STEP
Each trigger event triggers one sweep step. The frequency
increases by the value entered with [:SOURce<hw>]:SWEep[:
FREQuency]:STEP[:LINear] (linear spacing) or [:
SOURce<hw>]:SWEep[:FREQuency]:STEP:LOGarithmic
(logarithmic spacing).
*RST:
AUTO
Example: See Example "Setup an RF frequency or power sweep"
on page 643.
Manual operation: See "Mode" on page 172
[:SOURce<hw>]:SWEep[:FREQuency]:POINts <Points>
Sets the number of steps within the RF frequency sweep range.
See Chapter 6.2.1, "Correlating Parameters in Sweep Mode", on page 164.
SOURce Subsystem