Page #102 background imageLoading...
Page #102 background image
Function Variants Filling Scale
6.2.2 Function Keys
With the Filling Scale, the function keys are assigned as follows:
'Start Filling'
F1 key: 'Start'
'Stop Filling'
F2 key: 'Stop'
Resume filling with F1 = Start.
'Select material, enter setpoint'
F3 key: 'MatSet'
'Print Sub-total'
F4 key: 'PrintBal'
'Abort Filling'
F5 key: 'Abort'
'Print Total/Clear Balance'
F6 key: 'PrinTot'
6.2.3 Inputs and Outputs
Inputs:
Phys. Signal Function:
In 1: PLS-DIn1 Start
In 2: PLS-DIn2 Stop
In 3: PLS-DIn3 Abort
In 4: PLS-DIn4 Quit event message
n/a PLS-DIn5 Print Total/Clear Balance
Outputs:
Phys. Signal Function:
Out 1: PLS-DOut1 Full feed
Out 2: PLS-DOut2 Dribble feed
Out 3: PLS-DOut3 Discharge Contact
Out 4: PLS-DOut4 Ready to operate (no fault)
AnalogOut n/a Depending on choice
BV-H2313 GB 0630 DISOMAT
®
Opus – Operating Manual
- 96 - © Schenck Process GmbH, Darmstadt