Event Messages Event Message Construction
7 Event Messages
The DISOMAT displays hints on operating sequence and scale information in
alternating mode, e.g.
A0209:Powerfail
Designed to inform you about important events, these hints require a certain reaction.
Simple cases are designed for information only, severe cases, e.g. critical faults in
operation, require to be remedied and acknowledged.
For you to be able to classify these hints, every event message is assigned to an
event class identified by a code letter.
Hints of the following event classes are displayed:
Event Class Code Significance Required Reaction
Message M
Informative
Note
Warning W
Uncritical
Acknowledge *)
Alarm A
Critical
Acknowledge *)
Fault S
Very critical
Acknowledge after password input *)
nowledge event message before cause of fault has been
identified!
uction
as follows:
KNNT ID
s)
r (2 digits)
nt.
t is output. Optionally, an ID number (ID) can be output
esigned to specify the cause of the reported event. After the double point, the event
output in text form.
*) Never ack
7.1 Event Messag
Event messages are construc
e Constr
ted
T[- ]:Text
K
= Class (1 digit)
NN
= Event number (2 digit
TT
= Task numbe
-ID
= Optional ID number
:Text
= Event text
The first letter (K) is the code letter of the event class currently assigned to the eve
The next 2-digit number (NN) is the unambiguous code of the reported event
(=consecutive number of all event texts). Next, the 2-digit number (TT) of the task
having started the even
d
is
DISOMAT
®
Opus – Operating Manual 0630 BV-H2313 GB
© Schenck Process GmbH, Darmstadt - 131 -