Function Variants Crane Scale
6.4.4 Standard Operating Sequence
This item reflects a typical operating sequence of a crane scale:
Action
Display (e.g.)
Key; Comments
1. DISOMAT B plus must
be in home position!
Set display type: 'NET'
G 0.0 kg If scale display does not read zero:
->'Zero Scale' key
2.Hook on ropes or cross-
members, acquire tare.
G 103.5 kg
'Acquire Tare' key
Net T 0.0 kg
Scale is tared
3. Pick up load. 205.0 kg Scale shows NET weight. Net T
4.If need be, enter weigh
packaging or shopping
pallets as manual tare
value, or select value from
list of Fixed Tare values.
Not necessary if it
t of
em 2 has
en performed.
do.
put' key or 'Fixed
Tare' selection
be
'Manual Tare In
or
A quire input with key
do.
c
5. If need be, enter string.
do.
'Enter String' key
6. Weigh and print.
do.
+
Print or store weigh data. Relieve
crane to perform next weighing
operation.
7. Totally relieve scale.
8. Clear tare memory.
G 308.5 kg
Weighing is complete. Remove load
from scale, and scale is ready for
next weighing operation.
DISOMAT
®
Opus – Operating Manual 0630 BV-H2313 GB
© Schenck Process GmbH, Darmstadt - 111 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenck process Disomat Opus and is the answer not in the manual?

Schenck process Disomat Opus Specifications

General IconGeneral
BrandSchenck process
ModelDisomat Opus
CategoryControl Panel
LanguageEnglish

Related product manuals