Setting Mode Setting Using Calibration Password
5.4.2 Fct. 441:Calibration Parameters
The calibration parameters determine the scale characteristics. Changes at
this menu item are possible only if
• calibration has been prepared as described at Item Fct.
44_SCALE and
• calibration password has been entered.
After any change to calibration parameters, recalibration may be
necessary.
5.4.2.1 Operating Sequence
Use DIRECTION KEYS to go to menu item
441:SCALE
Calibration Parameters
and acknowledge with [ENTER] key.
Calibration parameters are divided into two blocks.
First enter Block 1 parameters. Change parameter and acknowledge with [ENTER] to
go to next parameter. After last parameter of Block 1, program returns to the first, for
you to change.
Block 1 parameters:
• Unit
• Full Scale
• Increment Value
• No-Motion Difference
• Zero Setting Range
• Overrange
• F-Mechanical
• F-Calibration
• L/C Rated Capacity
• Load Cell Number
• L/C-K [mV/V]
• Deadload
• Legal-For-Trade
Terminate calibration parameter input in Block 1 with [OK] key to acquire changes.
Brief display is output, e.g. ' 3000 Increments'. If you exit function with [ABORT] key,
changes are not acquired.
Operate [ENTER] key, and Block 2 calibration parameters are offered, for you to
change.
• Scale ID
• Class
• Gravity Deviation
• User-def. MIN load