Setting Mode Setting Using Calibration Password
5.4.6.2 Parameter 'Minimum Number of Days'
Display: Min. no. days 90
Input: Minimum value = 90 days (required by Board of Trade)
Maximum value = 730 days (2 years)
Function: Defines minimum storage period of legal-for-trade values in
days. Relevant only if local legal-for-trade memory
(VMM20400) is used.
The two MB internal legal-for-trade memory can store approx.
500 weighing operations per day over a period > 90 days. If
legal-for-trade memory is full and contains legal-for-trade
data younger than 90 days, an event message is output.
DISOMAT cannot be used for certified applications at the
time being.
Note: If legal-for-trade memory is used and weigh data storage fails, an event
message is output (A2305: Legal-for-trade memory FULL).
BV-H2313 GB 0630 DISOMAT
®
Opus – Operating Manual
- 90 - © Schenck Process GmbH, Darmstadt