Setting Mode Setting Using Configuration Password
Scroll field for selection of interface to be used appears:
4333:Secondary Display
Interface
Off
Other possibilities:
• S1, S2, S3
Select desired interface and acknowledge with [ENTER] key.
Operate [OK] key to acquire settings, and secondary display including interface
assignment is configured.
5.3.2.7 Fct. 4334:Fieldbus
If your DISOMAT is connected to a Process Management System (PMS) via fieldbus,
select protocol to be used and set parameters accordingly using this function.
Operating Sequence
Start function and select protocol to be used in scroll field:
4334:Fieldbus
Protocol
Off
Select from
• 'Off' | 'Profibus-DP' | 'Modbus'| 'DeviceNet'| 'Modbus/TCP'
Acknowledge selection with [ENTER] key.
Depending on protocol selected, some parameters must be set:
a) Profibus-DP
Parameter Input
Own address __8
ID number 0
Text block Off
4 bytes
20 bytes
Data format IEEE
Siemens KG
Timeout _10.0s
b) Modbus
Parameter Input
Own address __8
Reference value ____1
Maximum value _______1
Interface Off
S1
S2
S3
Timeout _10.0s
BV-H2313 GB 0630 DISOMAT
®
Opus – Operating Manual
- 68 - © Schenck Process GmbH, Darmstadt