Function Variants Discharge Scale
The PLS-DIn or PLS-DOut
fi
signals are used to control the scale by computer or
eldbus. They function at the same time as the physical inputs or outputs.
Exception: PLS-DIn5 Print Total/Clear Balance
6.3.4 Standard Operating Sequence
This e lar operating activities, i.e.
Print weigh data.
egular activities, e.g. enter setpoint and string, see manual BV-H2313, Item
u can stop feeding at any time, restart and complete, or abort it.
ery weighing operation (aborted or complete) is balanced automatically.
ts a typical operating sequence of a Discharge Scale.
it m explains the regu
• Perform feed operation
•
For other r
4.2.
Feeding
Feeding starts and normally continues until feeding is complete. Before start of
feeding (F3 key) , enter or check setpoint.
Yo
Ev
If feeding is complete, a weighing report is printed.
This items reflec
Action
Display (e.g.) Key(s); Comments
1. DISOMAT must be in
home position!
G 3.5 kg
2. Select material type and
enter setpoint.
'MatSet' key
3. Start discharging. G 3.5 kg
apr. 1sec.
Net T 0.0 kg
'Start' key
Scale waits for no-motion and tares
automatically.
Scale
isch inues automatically
is tared.
D arging cont
until setpoint is reached.
4. If required, stop
discharging.
4004:Filling
topped
lashes for 20 sec.)
55.5 kg
weight already
discharged
W
S
(f
Net T
'Stop' key
Continue discharging with
'Start' key
BV-H2313 GB 0630 DISOMAT
®
Opus – Operating Manual
- 104 - © Schenck Process GmbH, Darmstadt