Setting Mode Fct. 5b:Reset All(Restart)
5.5 Fct. 5b:Reset All(Restart)
Restart is required, for instance, if recommended by event messages of Class 'S'
(Fault).
ATTENTION: Perform restart right before completing commissioning. After restart of
DISOMAT
particularly ought
to complet
, ONLY event message "A03XX Restart" may be available. Any other event,
parameter errors, must be remedied before commissioning can be br
ion.
linkages) are
All data in main memory are overwritten.
Restart ('Reset all') loads all parameters from EEPROM memory into main
memory (RAM). In EEPROM, data (parameter values, function block
stored fail-safe.
uence
ng system, enter Restart password (see Item 5.1). After successful
put, another menu item appears in SERVICE menu:
Operating Seq
Before restarti
in
5b:SERVICE
Reset All
Start with [ENTER] key, and system prompts:
5b:Reset All
Acknowledge
Yes
Acknowledge with [ENTER] key, or enter 'No'.
If you select 'Yes', the hint
5b:Reset All
Restart
is displayed for some seconds before DISOMAT outputs A0309-99:Restart and
returns to home position.
Acknowledge with [ACK] key, and DISOMAT is again ready to operate.
BV-H2313 GB 0630 DISOMAT
®
Opus – Operating Manual
- 92 - © Schenck Process GmbH, Darmstadt