Function Variants Weighbridge ZEUS
In materials file, you can additionally
• Create data
i.e. assign numbers 1...25 to material name, and
• Clear mat. totals
i.e. process cumulative totals.
You can also select
• Text prompt
to replace prompt
MAT. :
by any prompt text of your choice.
For data processing functions, see menu item 58 "FILES". No password is required.
6.6.8 Hints, Possible Events
• Set printer to on-line. If not, certain outputs are buffered and printed only if
printer is reset to on-line. However, there is the danger of weigh data getting
lost.
• Vehicle Found message
The vehicle with the indicated vehicle number is in plant and has been first-
weighed. Perform second weighing or delete input in First Weighings File.
• Value Too High message
You have entered a vehicle number outside range 1...40 or, with vehicle
stored in Fixed Tare File, out of range 41...65.
• M0710:Zero-Error message
Scale can be zeroed only if totally unloaded, i.e. if display does not show more
than +3%, or not less than -1% of rated capacity range.
6.6.9 Deleting/Handling Error Messages
Some error messages are designed to warn you by periodic overwrite of display field
that a response is absolutely required. Before you acknowledge a message of this
kind, remove cause of fault. Then you can acknowledge event by operating the
'Acknowledge Event' keys
+ .
6.6.10 Deselect 'Release Weighing Operation' Prompt
The prompt before printout 'Contin.: Weigh/Abort' can be deselected in menu tree at
the function '421:Parameters' item for the respective type of weighing (first, second,
single weighing). Enter parameter password.
DISOMAT
®
Opus – Operating Manual 0630 BV-H2313 GB
© Schenck Process GmbH, Darmstadt - 127 -