Setting Mode Setting Using Parameter Password
Input fields for the following parameters are output one after the other:
Parameter Default Function
Prefill value +_0,00
Changeover from dribble feed to full feed upon smooth
start
Pre-act contact +_0,00 Full feed cut-off point; value related to main contact
Main contact +_0,00 Dribble feed cut-off point; value related to setpoint
Tolerance _0,00 Amissible tolerance value related to setpoint
Optimization
factor
0,00 Correction of main contact
Enter desired values and acknowledge with [OK] key.
5.2.3 Fct. 48:Fixed tare input
Sometimes you use the '7:Select fixed tare' function during weighing. For you to be
able to select, first enter values using this function.
You can store up to 9 different fixed tare values.
Operating Sequence
After call of function, current value of first parameter is displayed:
48:Fixed tare input
Fix1 __0,0kg
Enter desired value and operate [ENTER] key.
Display shows current value of second parameter:
48:Fixed tare input
Fix2 __0,0kg
Continue with Fix1' to 'Fix9'.
Acquire data and exit function with [OK] key.
5.2.4 Fct. 5c:Activate DISOPLAN Interfaces
• This function lets you activate the Service/DISOPLAN interface on general
interface S1. If another function is already active on this interface, e.g. printer
output, the interface is removed from the corresponding system section.
• Function activated, DISOPLAN can configure your system using the interface.
• For interface S1 to return to general system mode, reset device (power off
/on)!