Setting Mode Setting Using Parameter Password
Code Table
Code Description
B Output current Gross weight OR first Gross weight used subjected to format
change
B2 Output "B2" or print second Gross weight subjected to format change
BI Output balance total ( = total of 10 material balances); printer output, e.g.
12345,67kg SU;
BIn Output material balance; n = 1 ... 10;
BZ Output entered string (max. 25 characters) or transmit (max. 30 characters);
BZn Output entered string, or transmit; n = 1 ... 5 (BZ1 max. 25 characters)
Cn Output ASCII character to printer; n = 1 ... 255 (decimal);
e.g. C65 = 'A'; also for transfer of control characters to printer, e.g. C7 =
BELL;
D Output current date; printer output, e.g. 31.01.00;
D4 Output current date as per new standard, e.g. 2000-01-31;
DG Output current material flow value dW/dt;
Fn Output <n> page feeds on printer; n = 1 ... 99;
LN Output consecutive number of weighing
Mn Add printer pattern variable <n> to current print pattern, i.e. if the last print
pattern variable in Print Pattern 3 is M4, printout continues using Print Pattern
4. For printout, Print Patterns 3 and 4 form a unit, e.g. "Print Repeat" operates
as expected.
N Output current Net weight value OR first Net weight subjected to format
change.
In certified applications, permitted only in conjunction with G and T
N2 Output "N2" OR printout of second Net weight subjected to format change.
NE With tared scale: Output current Net weight OR first Net weight subjected to
format change.
With non-tared scale: Output current Gross weight OR first Gross weight
subjected to format change.
NOTE: With certified scales, always use NE.
NE2
With tared scale: Output "NE2" OR second Net weight subjected to format
change.
With non-tared scale: Output "NE2" OR second Gross weight subjected to
format change.
NOTE: With certified scales, always use NE.
_n Create <n> blanks between single outputs;
_ = blank; n = 1 ... 99;
If no '_n' is entered between single codes, 1 blank is always output.
Pn Set absolute column position for next printout; n = 1 ... 132;
RG Output current weighing range number: 1, 2 or 3
Rn Repeat preceding character n times; n = 1 ... 99;
e.g.: ,-,R7 repeats character '-' seven times ==> Printer output: -------
RD Output date when first weight transferred to format conversion has been
recorded (acquired by scale), e.g. weight stored in vehicle first weighing file.
RU Output time when first weight transferred to format conversion has been
recorded.
RD2 Output date when second weight transferred to format conversion has been
recorded (acquired by scale).
BV-H2313 GB 0630 DISOMAT
®
Opus – Operating Manual
- 50 - © Schenck Process GmbH, Darmstadt

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenck process Disomat Opus and is the answer not in the manual?

Schenck process Disomat Opus Specifications

General IconGeneral
BrandSchenck process
ModelDisomat Opus
CategoryControl Panel
LanguageEnglish

Related product manuals