Setting Mode Setting Using Configuration Password
Printers:
Local Printer
Output data to be printed.
No data transmission and printer monitoring
Remote Printer
Transfer data using secured protocol and monitored printer. Specially
designed for certified applications where printout cannot be
compared to display. Only the genuine SCHENCK remote printers
DISOPRINT...F3 are suitable.
DP 10
Protocol-controlled transmission to DISOPRINT 10 or tally-tape
printer.
With tally-tape printers, an ETX must follow after form feed (print
pattern formatting).
Operating Sequence
After start of function, system outputs a scroll field for selection of the interface for
printer connection.
4332:Printer
Printer Interface
Off
There are the following possibilities:
Off
No printer connected
S1
S2
S3
Acknowledge selection with [ENTER] key.
Scroll field for printer selection appears:
4332:Printer
Protocol
Local Printer
There are the following possibilities:
Local printer
See above
Remote printer
ditto
DP 10
Acknowledge selection with [ENTER] key.
Scroll field for input of printout line number appears:
4332:Printer
Page lines
200
Enter after how many lines a page feed is to be performed automatically.
Scroll field for printout of page header appears:
4332:Printer
Print Page Header
Yes
If you have defined a page header using function '463:Page Header Format' , select
from case to case whether this header is to be printed, or not.
BV-H2313 GB 0630 DISOMAT
®
Opus – Operating Manual
- 66 - © Schenck Process GmbH, Darmstadt

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenck process Disomat Opus and is the answer not in the manual?

Schenck process Disomat Opus Specifications

General IconGeneral
BrandSchenck process
ModelDisomat Opus
CategoryControl Panel
LanguageEnglish

Related product manuals