Figure 103: Object detection/object width
Select one of the following n settings for the object detection/object width and
enter the number of n beams:
n object is larger than or equal to n beams:
The output becomes active when the configured number of beams or more has
been blocked.
n object is smaller than or equal to n beams:
The output becomes active when the configured number of beams or less has
been blocked.
= n object is equal to n beams:
The output becomes active if the exact number of configured beams is blocked.
The object size that has been set is shown in the Simulation area. It can be changed
using the mouse.
Figure 104: Setting the object size with the mouse