6 Commissioning
6.1 Mechanical alignment of sender and receiver
After mounting and electrical installation, the sender and receiver must be aligned with
each other. No objects should be located between the sender and the receiver. The
light path must be clear.
Alignment with the QuickFix bracket
With the QuickFix bracket (see "Accessories", page 170), you have the following adjust‐
ment options:
Adjust vertically (H)
Figure 47: Alignment with the QuickFix bracket
Alignment with the FlexFix bracket
With the FlexFix bracket (see "Accessories", page 170), you have the following adjust‐
ment options:
Adjust vertically (H)
Rotate (±15°)