EasyManua.ls Logo

SICK MLG-2 ProNet - Lost Beams Hold (LBH) Evaluation Mode; SOPAS et - Function Blocked Beams Hold (BBH)

SICK MLG-2 ProNet
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameterizing the function Blocked Beams Hold (BBH) via SOPAS ET
Figure 140: SOPAS ET - Function Blocked Beams Hold (BBH)
In SOPAS ET, click on the Beam evaluation expandable menu in the right-hand
window.
In the Evaluation mode area, select the Blocked Beams Hold (BBH) evaluation mode.
The message Blocked Beams Hold selected. is displayed in the Configuration area. This
function only affects the selected basic functions.
In the BBH beam function area, activate the beam functions for which the Blocked
Beams Hold evaluation mode will be used.
If the evaluation mode is to be activated and deactivated using a hardware input,
check the Use digital input to activate BlockedBeamsHold box.
Select the desired digital input from the drop-down list.
Please note that you can only assign one function to an input. If necessary, you
must deactivate the Use digital input to start teach process option in the Teach-in
expandable menu.
In the left-hand window, on the tab E/A, the beam functions for which the output
mode has been selected are marked with (BBH) . In the Status Ein-/Ausgänge area,
the message TRIGGER_BBH_MODE is displayed if the evaluation mode BBH has
been activated via an input.
8.8.2 Lost Beams Hold (LBH) evaluation mode
Prerequisites
Expert function level
8 CONFIGURATION WITH SOPAS ET
144
O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet 8018748.1Q3I/2024-12-18 | SICK
Subject to change without notice

Table of Contents

Related product manuals