Value Name Description
36 NCBB Zone 1 Number of consecutive beams blocked in Zone 1 (e.g.,
for object detection).
If there are multiple objects in the detection area, the
greatest number of consecutive beams blocked is dis‐
played.
37 CBB Zone 1 Beam number of the central beam blocked in Zone 1
(e.g., for measuring an object position)
38 NBB Zone 2 Total number of beams blocked in Zone 2 (e.g., for
object detection)
39 FBB Zone 2 Beam number of the first beam blocked in Zone 2 (e.g.,
for height classification of a hanging object)
40 LBB Zone 2 Beam number of the last beam blocked in Zone 2 (e.g.,
for object height measurement)
41 NCBB Zone 2 Number of consecutive beams blocked in Zone 2 (e.g.,
for object detection).
If there are multiple objects in the detection area, the
greatest number of consecutive beams blocked is dis‐
played.
42 CBB Zone 2 Beam number of the central beam blocked in Zone 2
(e.g., for measuring an object position)
43 NBB Zone 3 Total number of beams blocked in Zone 3 (e.g., for
object detection)
44 FBB Zone 3 Beam number of the first beam blocked in Zone 3 (e.g.,
for height classification of a hanging object)
45 LBB Zone 3 Beam number of the last beam blocked in Zone 3 (e.g.,
for object height measurement)
46 NCBB Zone 3 Number of consecutive beams blocked in Zone 3 (e.g.,
for object detection).
If there are multiple objects in the detection area, the
greatest number of consecutive beams blocked is dis‐
played.
47 CBB Zone 3 Beam number of the central beam blocked in Zone 3
(e.g., for measuring an object position)
48 NBB Zone 4 Total number of beams blocked in Zone 4 (e.g., for
object detection)
49 FBB Zone 4 Beam number of the first beam blocked in Zone 4 (e.g.,
for height classification of a hanging object)
50 LBB Zone 4 Number of consecutive beams blocked in Zone 4 (e.g.,
for object detection).
If there are multiple objects in the detection area, the
greatest number of consecutive beams blocked is dis‐
played.
51 NCBB Zone 4 Beam number of the central beam blocked in Zone 4
(e.g., for measuring an object position)
52 CBB Zone 4 Total number of beams blocked in Zone 4 (e.g., for
object detection)
53 User defined 1 User defined 1
54 User defined 2 User defined 2
55 User defined 3 User defined 3
56 User defined 4 User defined 4