service.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
12-67
Nur für den internen Gebrauch Service
Guided Maintenance
09-061 !Overcurrent on
power controller
on (SLMO)
Overcurrent on the
specified SLMO
board.
Check the power and line
on the terminal and power
supply unit.
Replace hardware if nec-
essary.
09-062 !Overcurrent on
power controller
off (SLMO
Overcurrent on the
specified SLMO
board has been
corrected.
None
09-065 !Out of buffers for
card error on
Insufficient pool
capacity on the
specified SLMO
board.
Check lines and terminals.
Set up a default trace.
High traffic load: –>
Distribute load to sev-
eral boards.
Board is faulty: -> Re-
place board.
09-066 !Out of buffers for
card error off
Insufficient pool
capacity on the
specified SLMO
board has been
corrected.
None
Error Class 11 – General Messages
11-058 !Too many L1 er-
rors
Too many layer 1
errors.
Check the lines, terminal,
and port.
A short circuit may have
occurred.
Error Class 12 – Processor Exceptions
12-000 Initial Stack Ptr Reset: Initial Stack
Pointer
Create a trace.
Create a stack dump.
Save a snapshot.
12-001 Initial Prg.
Counter
Reset: Initial Pro-
gram Counter
Create a trace.
Create a stack dump.
Save a snapshot.
Table 12-7 HiPath 3000 Class B Error Messages
No. HiPath 3000/
5000 Manager E:
Event Log Entry
Meaning Required Measures Note