Guided Maintenance
09-048 !bitslip error on
(TMS2M)
A bit slip has oc-
curred on an ISDN
line.
Check the S
2M
line.
If necessary, reload the
board or perform a hard re-
start.
If the error persists, set up
an ISDN trace.
The problem
may be caused
by asynchro-
nous internal
and external
clock rates.
Data loss possi-
ble/connection
may be terminat-
ed.
09-049 !bitslip error off
(TMS2M)
The bit slip on the
ISDN line has been
corrected.
None
09-050 !loss of synchroni-
zation error on
(TMS2M)
A synchronization
error has occurred.
Check the S
2M
line.
If necessary, reload the
board or perform a hard re-
start.
If the error persists, set up
an ISDN trace.
The problem
may be caused
by asynchro-
nous internal
and external
clock rates.
Data loss possi-
ble/connection
may be terminat-
ed.
09-051 !loss of synchroni-
zation error off
(TMS2M)
The synchroniza-
tion error has been
corrected.
None
09-058 !Self test error on
(SLMO)
Error while self-
testing the speci-
fied SLMO board.
If necessary, replace the
board or change the slot.
09-059 !Self test error off
(SLMO)
Error while self-
testing the speci-
fied SLMO board
has been correct-
ed.
None
Table 12-7 HiPath 3000 Class B Error Messages
No. HiPath 3000/
5000 Manager E:
Event Log Entry
Meaning Required Measures Note