Guided Maintenance
09-037 !slip detected off
(STMD)
The bit slip on the
ISDN line has been
corrected.
None
09-038 !alarm indication
signal error on
(TMS2M)
Alarm display: An
S
2M
error has oc-
curred.
Physical line/board
problem (too many
CRC/SLIP errors).
Check the S
2M
line and
board.
Replace the board if nec-
essary.
If the error persists, set up
an ISDN trace.
09-039 !alarm indication
signal error
off(TMS2M)
Alarm display: The
S
2M
error has been
corrected.
None
09-042 !no signal error on
(TMS2M/STMD)
Alarm display: An
S
2M
error has oc-
curred.
No physical con-
nection available.
Check the S
2M
line and
board.
If necessary, reload the
board or perform a hard re-
start.
If the error persists, set up
an ISDN trace.
09-043 !no signal error off
(TMS2M/STMD)
Alarm display: The
S
2M
error has been
corrected.
None
09-044 !receive remote
alarm error on
(TMS2M)
Alarm display: An
S
2M
error has oc-
curred.
Physical problem
with the communi-
cation partner (too
many CRC/SLIP
errors).
Check the board and part-
ner system or arrange for a
technician to do so.
09-045 !receive remote
alarm error off
(TMS2M)
Alarm display: The
S
2M
error has been
corrected.
None
Table 12-7 HiPath 3000 Class B Error Messages
No. HiPath 3000/
5000 Manager E:
Event Log Entry
Meaning Required Measures Note