A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
3-147
Nur für den internen Gebrauch Boards for HiPath 3000
Peripheral boards
Base Station Power Supply via One U
P0/E
Interface
Connect the base station to a free interface on SLC16N as shown in Figure 3-53. Be careful
not to exceed the maximum connection cable lengths (1000 m for 2 x 0.6 mm).
Figure 3-53 Base Station Power Supply via One U
P0/E
Interface (not for U.S.)
a
b
1
CABLU
MDFU, MDFU-E
1
2
U
P0/E
BS3/1 for in-
doors
Splitting
strip
HiPath 3550
SLC16N