Function Manual
01/2017
103
Program status: Interrupted
Channel status: Interrupted
Dry run feed rate selected
Feed rate override selected for rapid traverse
DB1700.DBX0002 .0 Skip-block selected
INT1
Interrupt no. not allocated
ASUP version not possible
INT2
Interrupt no. not allocated
ASUP version not possible
Brief description
Compensations
The following axis-specific compensation functions can be activated for the control system:
● Backlash compensation
● Interpolatory compensation
– leadscrew error and measuring system error compensation (LEC)
● Following error compensation (speed feedforward control)
● Friction compensation (quadrant error compensation)
These compensation functions can be set for each machine individually with axis-specific machine data.