EasyManuals Logo

Siemens SINUMERIK 828D Function Manual

Siemens SINUMERIK 828D
1799 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #102 background imageLoading...
Page #102 background image
A3: Axis Monitoring, Protection Zones
2.2 Axis monitoring
Basic Functions
102 Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Changing the working area limitation
Working area limitation through setting data
HMI user interface: Operating area "Parameter"
Automatic modes:
- Changes: possible only in the RESET state
- Effective: immediately
Manual operating modes:
- Changes: always possible
- Effective: at the start of the next traversing motion
Programmed working area limitation
The working area limitation can be changed in the part program via G25or G26 <Axis identifier> <value>. The
change takes effect immediately.
The new working area limitation value is retained after and NC RESET and POWER ON if the back-up process
has been activated in the NCK's retentive data storage for SD43420 and SD43430:
MD10710 $MN_PROG_SD_RESET_SAVE_TAB[0] = 43420
MD10710 $MN_PROG_SD_RESET_SAVE_TAB[1] = 43430
Reset position
The reset position for the working area limitation (WALIMON or WALIMOF) is configurable via:
MD20150 $MC_GCODE_RESET_VALUES (RESET position of G groups)
2.2.7.3 Working area limitation in WKS/ENS
Application
The working area limitation in the workpiece coordinate system (WCS) or adjustable zero system (AZS) is mainly
intended for defining working area limits in conventional lathes. This allows "stops" to be defined for the channel
axes, thereby enabling workpiece-specific limits to be defined for the working area.
Working area limitation group
There are working area limitation groups available containing all the data which is of relevance to the working
area limitation. As such, there is no need to write the working area limitations afresh every time while switching
the transformation or the active frame, for example.
A working area limitation group comprises the following data:
WALIMON
Working area limitation ON
or
WALIMOF
Working area limitation OFF

Table of Contents

Other manuals for Siemens SINUMERIK 828D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 828D and is the answer not in the manual?

Siemens SINUMERIK 828D Specifications

General IconGeneral
Control TypeCNC
Operating SystemWindows Embedded
ProcessorIntel Atom
Display10.4" color TFT display
InterfacesEthernet, USB
ProgrammingShopMill, ShopTurn
Operation Panel Size10.4"
Protection ClassIP65
PLC Memory2 MB
Spindle Capacity4 spindles
Hard DriveCompactFlash

Related product manuals