Z1: NC/PLC interface signals
19.9 PLC basic program (P3)
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
1697
19.8.2 Signals from NC (DB10)
19.9 PLC basic program (P3)
To describe the NC/PLC interface signals, refer to:
References:
Functions Manual, Basic Functions; PLC Basic Program (P3)
Chapter: "Signal/Data Specifications"
Special cases,
errors, ......
The EMERGENCY STOP state cannot be reset using the interface signal:
DB21, ... DBX7.7 (reset).
Corresponding to .... DB10 DBX56.1 (EMERGENCY STOP)
DB10 DBX106.1 (acknowledge EMERGENCY STOP)
DB11 DBX0.7 (mode group reset)
DB10
DBX106.1 EMERGENCY STOP active
Edge evaluation: no Signal(s) updated: cyclic
Signal state 1 or
edge change
0 1
The NC is in the EMERGENCY STOP state.
Corresponding to .... DB10 DBX56.1 (EMERGENCY STOP)
DB10 DBX56.2 (acknowledge EMERGENCY STOP)
DB10
DBX56.2 Acknowledge EMERGENCY STOP
,6DNQRZOHGJH(0(5*(1&<6723
,6(0(5*(1&<6723DFWLYH"
,65(6(7
,65HVHWKDVQRHIIHFW
,6$FNQRZOHGJH(0(5*(1&<6723DQG5(6(7UHVHW(0(5*(1&<6723DFWLYH
,6$FNQRZOHGJH(0(5*(1&<6723KDVQRHIIHFW