R1: Reference point approach
15.2 Axisspecific referencing
Basic Functions
1202 Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Cancellation of reference point approach
In axis-specific reference point approach, the machine axis is traversed in the channel that was assigned as the
master channel of the machine axis.
MD30550 $MA_ AXCONF_ASSIGN_MASTER_CHAN
For aborting the reference point approach, either mode group reset or channel reset for the master channel of the
machine axis must be activated:
DB11, ... DBX0.7 (mode group reset)
DB21, ... DBX7.7 (channel reset)
All machine axes that have not yet successfully completed reference point approach when the action is cancelled
remain in status "Not referenced":
DB31, ... DBX60.4 (referenced / synchronized 1)
DB31, ... DBX60.5 (referenced / synchronized 2)