B1: Continuouspath Mode, Exact Stop, LookAhead
3.3 Continuous-path mode
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
159
No intermediate rounding blocks
An intermediate rounding block is not inserted in the following cases:
The axis stops between the two blocks.
This occurs when:
- The following block contains an auxiliary function output before the movement.
- The following block does not contain a path movement.
- An axis is traversed for the first time as a path axis for the following block when it was previously a
positioning axis.
- An axis is traversed for the first time as a positioning axis for the following block when it was previously a
path axis.
- The previous block traverses geometry axes and the following block does not.
- The following block traverses geometry axes and the previous block does not.
- Before tapping, the following block uses G33 as preparatory function and the previous block does not.
- A change is made between BRISK and SOFT.
- Axes involved in the transformation are not completely assigned to the path motion (e.g. for oscillation,
positioning axes).
The rounding block would slow down the part program execution.
This occurs:
- between two very short blocks.
Since each block requires at least one interpolation cycle, the added intermediate block would double the
machining time.
- If a block transition with G64 (continuous-path mode without rounding) can be traversed without a
reduction in velocity.
Corner rounding would increase the machining time. This means that the value of the permitted overload
factor (MD32310 $MA_MAX_ACCEL_OVL_FACTOR) affects whether a block transition is rounded or not.
The overload factor is only taken into account for rounding with G641 / G642. The overload factor has no
effect in the case of rounding with G643 (this behavior can also be set for G641 and G642 by setting
MD20490$MC_IGNORE_OVL_FACTOR_FOR_ADIS=TRUE).
Rounding is not parameterized.
This occurs when:
- in the case of G641 ADISPOS= 0 in G0 blocks (default!).
- In the case of G641 ADIS=0 in non-G0 blocks (default!).
- For transition from G0 to non-G0 or non-G0 to G0, the smaller of the values for ADISPOS and ADIS will
apply in the case of G641.
- For G642/G643, all axis-specific tolerances are zero.

Table of Contents

Other manuals for Siemens SINUMERIK 828D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 828D and is the answer not in the manual?

Siemens SINUMERIK 828D Specifications

General IconGeneral
Control TypeCNC
Operating SystemWindows Embedded
ProcessorIntel Atom
Display10.4" color TFT display
InterfacesEthernet, USB
ProgrammingShopMill, ShopTurn
Operation Panel Size10.4"
Protection ClassIP65
PLC Memory2 MB
Spindle Capacity4 spindles
Hard DriveCompactFlash