B1: Continuouspath Mode, Exact Stop, LookAhead
3.7 Tolerance and compression of G0 blocks
Basic Functions
208 Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Reading the tolerance factor
The G0 tolerance factor, effective in the part program or in the actual IPO block, can be read using system
variables.
For the display in the user interface, in synchronized actions or with a preprocessing stop in the part program
via the system variables:
Without preprocessing stop in the part program via system variable:
If no value with STOLF is programmed in the active part program, then these two system variables supply the
value set using MD20560 $MC_G0_TOLERANCE_FACTOR.
If no rapid traverse (G0) is active in a block, then these system variables always supply a value of 1.
$AC_STOLF Active G0 tolerance factor
G0 tolerance factor, which was effective when processing the
actual main run block.
$P_STOLF Programmed G0 tolerance factor