D1: Diagnostics tools
5.3 Service overview
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
279
Rampup function generator quick stop
Status display for rampup function generator quick stop.
Display corresponds to IS DB31, ... DBX92.1 ("Rampfunction generator rapid stop").
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
DC link state (on/off)
The display contains the following drive warning:
State 0: DC link voltage = ON
State 1: DC link voltage is below warning threshold.
The warning threshold corresponds to machine datum:
MD1604 $MD_LINK_VOLTAGE_WARN_LIMIT (DC link undervoltage warning threshold).
Enable pulses
Message indicating whether the drive pulses have been enabled.
Display corresponds to IS DB31, ... DBX93.7 ("Enable pulses").
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2).
Drive ready
Display of the current status of the selected drive.
State 0: The drive is not ready.
State 1: The drive is ready.
Display corresponds to IS DB31, ... DBX93.5 ("Drive Ready").
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
Display indicating the current rampup phase of the selected drive.
Meaning:
State 1: Ramp-up function generator quick stop is not active for the drive.
State 0: Ramp-up function generator quick stop is active. The drive is stopped without
a ramp function with speed setpoint = 0 and without pulse suppression.
State 0: The drive module pulses are suppressed. The axis/spindle can therefore not
be traversed.
State 1: The drive module pulses are enabled. The axis/spindle can now be traversed.