EasyManua.ls Logo

Siemens SINUMERIK 828D

Siemens SINUMERIK 828D
1799 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
H2: Auxiliary function outputs to PLC
8.16 Supplementary conditions
Basic Functions
466 Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Auxiliary function: M1 (conditional stop)
Overlapping of the parameterized output behavior
The parameterized output behavior of the auxiliary function M1 is overridden by the output behavior defined in the
following machine data:
MD20800 $MC_SPF_END_TO_VDI, Bit 1 (subprogram end / stop to PLC)
Part program blocks without traverse movement
In a part program block without a traverse movement, all auxiliary functions are output in a block immediately,
irrespective of their parameterized output behavior.
Bi
t
Value Description
1 0 The auxiliary function M01 (conditional stop) is always output to the PLC. A quick
acknowledgement is ineffective, because M01 is permanently assigned to the first
auxiliary function group and is therefore always output at the end of the block.
1 The auxiliary function M01 (conditional stop) is only output to the PLC, if the function:
"Programmed stop" is activated via the HMI user interface.
In the case of a quick acknowledgement, the M1 is output to the PLC during the motion.
While the function is not active, this does not interrupt continuous-path mode.