Table 3.3-3 Contact input/output/ analog output communication specification
Item
Specification
Contact
input
signal1,2,3
Electrical isolation
Photocoupler
Run/Stop signal
External switch signal
Operation mode request signal
(Contact input 3 fixed)
Rated input
voltage
DC24V
Operating voltage
range
DC21.6V to 26.4V
Rated input
current
5mA TYP
Input impedance
4.7kΩ
Contact output
signal
1,2,3,4,5,6
Rated load
voltage
AC48V or less /
DC30V or less
Signal of operating status
Alarm signal
TEMP READY signal etc *2
Maximum load
current
AC/DC 800mA or less *1
Minimum load
current
DC5V 10mA
Analog output
signal 1,2
Output voltage range
0V to +10V
-
Maximum output current
10mA
Maximum accuracy
±0.4%F.S. or less
DC24V output voltage
DC24V±10% 200mA MAX 1
(It can not be used for inductive load.)
1:The total load current must be 800 mA or less. To use the power from the device, the total load current
must be 200 mA or less.
2:Refer to “3.3.6 Wiring of the contact output signal

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks HRL100-A 40 Series and is the answer not in the manual?

SMC Networks HRL100-A 40 Series Specifications

General IconGeneral
BrandSMC Networks
ModelHRL100-A 40 Series
CategoryChiller
LanguageEnglish

Related product manuals