Chapter 19 Control Panel Setup (Panel)
1009
Operation Settings (Operation Menu)
Downstream key control block (MKS-8032 DSK Fader Module,
option)
Interchanging the [AUTO TRANS] and [CUT] buttons: To
interchange the [AUTO TRANS] and [CUT] buttons in the transition
control block, press the [Auto Trans/Cut Swap] button, turning it on.
Transition preview operation mode: For the operation mode of the
[TRANS PVW] button, select [Lock] or [Hold] in the <Trans Pvw>
group. The setting as to whether to use the “One-time mode” in which
the transition preview terminates when the transition completes, or to
use button control, is made on the switcher side (see page 1043).
[KEY] button operation mode for key source bus operations: For key
source bus operations, specify the operation mode of the [KEY] button
in the auxiliary bus control block in the <Key Source Bus Select
Mode> group, as follows.
Key: If you select this, the [KEY] button is always unlit, and this mode
allows only key signals to be selected with the cross-point buttons.
Video & Key: The [KEY] button is enabled, and either video or key
signals can be selected.
CCP-9000A-specific button settings: Press [CCP-9000 Button], and skip
to step 3.
3
If required, make the following settings.
DME channel selection mode: To set the mode when one of the [DME1]
to [DME4] buttons in the key delegation section is pressed to select the
DME channel, select either of the following in the <DME Select>
group.
Override: Forcibly select the selected channel. (Later selection takes
precedence).
Pre Select: It is not possible to select a channel that has already been
otherwise selected. (Earlier selection takes precedence.)
Operation mode of the [XPT HOLD] button in the key delegation
section: To set the operation mode of the [XPT HOLD] button in the
key delegation section, select either of the following in the <Xpt
Hold> group.
A/B Bus: When the [XPT HOLD] button is pressed, turning it on,
cross-point hold is enabled for the A and B buses only.
All Bus: When the [XPT HOLD] button is pressed, turning it on,
cross-point hold is enabled for all buses used on the bank being
currently operated.
(A/B buses, Key 1 to Key 8 buses, Utility 1/2 buses, external
DME bus, DME Utility 1/2 buses)