Chapter 20 Switcher Setup (Switcher)
1028
Signal Input Settings (Input Menu)
Signal Input Settings (Input Menu)
For setup relating to signal inputs, use the Switcher >Input menu.
To display the Input menu
In the Engineering Setup menu, select VF3 ‘Switcher’ and HF2 ‘Input.’
The status area shows source numbers and source names and through mode on/
off setting.
The following functions are available here.
Through Mode: Set the through mode for input. You can set this
independently for each primary input or premium input.
Video Process: Switch video processing on or off for each input signal, and
adjust the brightness, hue and so forth.
Matte Illeg. Color Limit: Switch the illegal limiter on or off for the signal
generated by the switcher internal matte generator.
FC Adjust: Select the conversion (up-conversion, cross-conversion, or
down-conversion) when the format converter is applied to an input.
Making Through Mode Settings
Notes
For a format converter dedicated input, it is not possible to select through
mode.
1
In the Switcher >Input menu, select the input signal to which the settings
apply.
Press directly on the list in the status area.
Press the arrow keys to scroll the reverse video cursor.
Turn the knob.
a) For primary inputs: 1 to 144
For premium inputs: 145 to 164 ((PREM1) to (PREM20) indicated after the number)
The selected input signal appears in reverse video.
2
To enable through mode, press [Through Mode], turning it on.
Knob Parameter Adjustment Setting values
1 Src No Input signal selection
1 and upwards
a)