Chapter 18 System Setup (System)
908
Setting the Signal Format (Format Menu)
Setting the Signal Format (Format Menu)
To set the format, that is, the frame frequency and number of scan lines handled
by each device, use the System >Format menu.
To display the Format menu
In the Engineering Setup menu, select VF1 ‘System’ and HF3 ‘Format.’
Notes
After changing any of the following settings, be sure to press [Execute] (or [FC
Format Execute] for changing the format converter signal format) to save the
new values. If you want to cancel the settings and return to the original state,
press [Clear] without pressing [Execute] or [FC Format Execute]. When you
press [Execute], some data is lost (such as frame memory images). If you press
[FC Format Execute], memory is not initialized, and this data is not lost.
Setting the Signal Format
Specify the signal format to be handled by the devices.
The combinations of signal formats that can be selected are as follows.
1
In the System >Format menu, select the device for operations.
Press directly on the list in the status area.
Press the arrow keys to scroll the reverse video cursor.
System Field frequency Effective number of scan lines
HD system 50 1080i
59.94
50 1080P
59.94
23.976 1080PsF
24
25
29.97
50 720P
59.94
SD system 59.94 480i
50 576i