Chapter 19 Control Panel Setup (Panel)
962
Overall Control Panel Settings (Config Menu)
To return all device selection button assignments to the factory
default state
In the Joystick/Trackball Module menu, press [Default].
Inhibiting Utility 2 Bus and Key Operations
You can inhibit operations on the utility 2 bus and keys 1 to 8 of the M/E and
PGM/PST banks by menu operations.
This inhibitions apply for the following control blocks.
Cross-point control block
Transition control block
Independent key transition control block
1)
1) Only when the Key1, 2, Key 3, 4, Key5, 6 or Key7, 8 are assigned by the Compact Key Module
Assign menu.
Notes
This operation cannot be done in the CCP-9000A.
1
In the Panel >Config menu, press [Operation Inhibit].
Operation Inhibit menu appears.
2
Press [M/E Operation Inhibit].
The M/E Operation Inhibit menu appears.
3
In the list in the status area, using any of the following methods, select the
switcher bank for which operations are to be inhibited.
Press directly on the desired switcher bank in the list.
Press the arrow keys to scroll the reverse video cursor.
Turn the knob.
4
In the <M/E Operation Inhibit> group, press the utility 2 bus or key button
([Util2 Bus] or [Key1] to [Key8]) for which operations are to be inhibited.
Knob Parameter Adjustment Setting values
1 Bank Switcher bank selection for
inhibiting operations
1 and upwards