Chapter 10 Special Functions
409
Multi Program 2
a) Keys 2 to 8 are common to main and sub.
Notes
Allow a transition to complete before carrying out main and sub delegation
switching.
The sub background A bus (utility 2 bus) is shared with wipe edge border fill.
Making a change to one affects the other.
Even if the wipe border width is set to the same numeric value for main and
sub, the same image is not obtained.
Restrictions on Using Multi Program 2 Mode
The following functions are not available for sub:
Data copy and swap
Default recall (except for parametric recall)
Re-entry is limited to five levels. Re-entry is not possible for main and sub
of the same M/E.
However, this restriction can be removed. For details, see “Enabling re-
entry between the main and sub sides of the same M/E bank” (page 406).
In the following cases, a transition using the fader lever may not be
performed correctly:
When the main and sub bus toggle modes are set differently
For a pattern mix, preset color mix, and so on
For an Internal bus link, GPI link, or External bus link, the “Utility 2” bus
cannot be selected.
Screen aspect, show key, and [MCRO ATTCH ENBL] button settings are
common to main and sub.
If a snapshot is recalled simultaneously for main and sub, or a keyframe is
executed simultaneously for main and sub, then for the following common
to main and sub the main settings are reflected.
Transitions Key priority Cannot be used
Transition
preview
Cannot be used
Preset color
mix
Color matte or video signal
selected on the utility 2 bus
Color matte only
Snapshots Cross-point
hold
Utility 2 cannot be set Utility 3 is added. BKGD
A/B and Key1 cannot be
set.
Control from an editor Same as standard mode Cannot be used
Operation setting for
switcher GPI inputs and
outputs
Same as standard mode Cannot be used
Item Main Sub

Table of Contents