Chapter 3 Signal Selection and Transitions
136
Executing a Transition
Timecode display mode: Values are shown as timecode values, consisting of
seconds and frames. In this display mode, a value entered in frame input
mode is converted for display as a timecode value. If the value consists of
four or more digits, the last digit is not shown.
Example: A value of 9 seconds 23 frames appears as “9.23” and a value
of 10 seconds 1 frame appears as “10.0.”
Setting the transition rate in the numeric keypad control block
Numeric keypad control block
1
In the numeric keypad control block, press the [TRANS RATE] button.
2
Press the region selection button for the M/E or PGM/PST bank for which
you want to set the transition rate, turning it on.
The numeric keypad control block display now shows the selected region
name and the current transition rate setting for the region.
3
With the numeric keypad, enter the transition rate.
Enter a value of up to three digits.
To clear the entry, press the [CLR] button.
4
Press the [ENTER] button.
TRANS RATE button
Region selection buttons
Display
Numeric keypad
ENTER button