Chapter 11 DME Operations
549
DME Special Effect Operations
Notes
On the MVE-8000A, Effect Gp 1 and Effect Gp 2 cannot be turned on at
the same time.
3
Press [Position/Size].
4
Set the mask source parameters.
The valid ranges of the parameter values depend on the combination of
signal format (SD/HD) and aspect ratio (4:3/16:9) selected in the system,
as follows.
•4:3 mode
a) This setting value is not supported on the MVE-8000A.
16:9 mode
a) This setting value is not supported on the MVE-8000A.
5
To invert the mask source, press [Invert], turning it on.
6
As required, set the modifiers for the mask pattern.
When turning [Aspect] on and adjusting the pattern aspect ratio
Knob Parameter Adjustment Setting values
1 H Horizontal position –8.00 to +8.00 (SD)
–24.00 to +24.00 (HD)
2 V Vertical position –6.00 to +6.00 (SD)
–18.00 to +18.00 (HD)
3 Size Size of mask 0.00 to 100.00
4 Soft Softness of mask 0.00 to 100.00
5 Pattern Pattern number
21, 24, 304
a)
Knob Parameter Adjustment Setting values
1 H Horizontal position –8.00 to +8.00 (SD)
–32.00 to +32.00 (HD)
2 V Vertical position –4.50 to +4.50 (SD)
–18.00 to +18.00 (HD)
3 Size Size of mask 0.00 to 100.00
4 Soft Softness of mask 0.00 to 100.00
5 Pattern Pattern number
21, 24, 304
a)
Knob Parameter Adjustment Setting values
1 Aspect Aspect ratio
–100.00 to +100.00