Chapter 19 Control Panel Setup (Panel)
989
Setting Button Assignments (Prefs/Utility Menu)
3
In the <Action> group, select the function you want to assign.
Menu Shortcut: Assign a frequently used menu to be recalled (menu
shortcut).
Utility Command: Assign a function on/off or similar operation (utility
command).
Macro Recall: Assign a macro register recall.
Shotbox Recall: Assign a shotbox register recall.
4
Depending on the selection in step 3, make the following settings.
When Menu Shortcut is selected: For the subsequent operations, see the
next item “Assigning a menu shortcut to a memory recall button”
(page 993).
When Utility Command is selected: A list of commands appears on the
right of the status area; using any of the following methods, select the
command you want to assign.
• Press directly on the list.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
a) When the Command parameter is set to Sw’er GPI Test Fire, Panel GPI Test Fire, DCU
GPI, or Test Fire
When Macro Recall is selected: Turn the knob to select the macro
register you want to assign.
When Shotbox Recall is selected: Turn the knob to select the shotbox
register you want to assign.
5
Press [Action Set].
This assigns the selected action, which is reflected in the status area.
Knob Parameter Adjustment Setting values
1 Bank Bank selection 1 to 4
2 Button No Control block button selection 1 to 24
Knob Parameter Adjustment Setting values
3 Command Utility command selection 1 and upwards
4
a)
GPI No GPI port number 1 and upwards
Knob Parameter Adjustment Setting values
3 Macro Macro register selection 1 to 250
Knob Parameter Adjustment Setting values
3 Shotbox Shotbox register selection 1 to 99