17
R3
SLM mode:
exposure time: 1..720 (in minutes)
VLM mode:
reserved
18
R4
SLM mode:
rolling time(1) in seconds
VLM mode:
reference level for acceleration in 0.01 dB re 1.0 µm/s
2
19
R5
SLM mode:
rolling time(2) in seconds
VLM mode:
reference level for velocity in 0.01 dB re 1.0 nm/s
20
R6
SLM mode:
reserved
VLM mode:
reference level for displacement in 0.01 dB re 1.0 pm
21
RPM_On
RPM measurement:
0 Off
1 on
22
RPM_Pulse
RPM pulse: 1÷360
23
Windscreen
SLM mode:
0 Off,
1 On,
VLM mode:
reserved
24
Compensation Filter
SLM mode:
compensating filter for microphones:
0 Off,
1 Free Field,
2 Diffuse Field,
3 Outdoor Environment,
4 Outdoor Airport
VLM mode:
reserved
25
VoltageInput
Voltage input:
0 Off
1 On
26
CurrentIEPE
IEPE current
0 Off
1 1.5 mA
2 4.5 mA
27
SplitMode
Logger files splitting mode:
0 - off.
-1 - The file is created for each measurement cycle.
15 - The file is created every 15 min synchronized to RTC.
30 - The file is created every 30 min synchronized to RTC.
60 - The file is created every 1 hour synchronized to RTC.
1440 - The file is created on the specified times.
28
SplitTime[1]
Logger files splitting time:
-1 - off.
0:1439 - Time in minutes.
Valid only if SplitMode is equal 1440.