RT60 results block (cf. Table B.1.32);
RT60 averaged results block (cf. Table B.1.33).
B.2.1. The contents of the logger file
The records with the results and the records with the state of the markers as well as the records with the breaks
in the results registration are saved in the files in the logger. All results are written in dB*100.
B.2.1.1. Record with the results
The contents of the record with the results depends on the selected measurement function and the value set
in the LOGGER position of the PROFILE x and SPECTRUM sub-lists. The following elements can be present
(in the given sequence):
1. flag record
<flags> - b0: 1- the overload detected, 0 - the overload not detected
2. results of the measurement from the first profile if the corresponding LOGGER position was active
(BufferP [1] in 0 or 0); up to six words are written:
SLM mode:
<result1> - Peak result, depending on the value of BufferP[1] (cf. Table B.1.12)
<result2> - Max result, depending on the value of BufferP[1] (cf. Table B.1.12)
<result3> - Min result, depending on the value of BufferP[1] (cf. Table B.1.12)
<result4> - Leq result, depending on the value of BufferP[1] (cf. Table B.1.12)
<result5> - LR1 result, depending on the value of BufferP[1] (cf. Table B.1.12)
<result6> - LR2 result, depending on the value of BufferP[1] (cf. Table B.1.12)
VLM mode:
<result1> - Peak result, depending on the value of BufferP[1] (cf. Table B.1.13)
<result2> - P-P result, depending on the value of BufferP[1] (cf. Table B.1.13)
<result3> - Max result, depending on the value of BufferP[1] (cf. Table B.1.13)
<result4> - RMS result, depending on the value of BufferP[1] (cf. Table B.1.13)
3. results of the measurement from the second profile if the corresponding LOGGER position was active
(BufferP [2] in Table B.1.12 or Table B.1.13); up to six words are written:
SLM mode:
<result1> - Peak result, depending on the value of BufferP[2] (cf. Table B.1.12)
<result2> - Max result, depending on the value of BufferP[2] (cf. Table B.1.12)
<result3> - Min result, depending on the value of BufferP[2] (cf. Table B.1.12)
<result4> - Leq result, depending on the value of BufferP[2] (cf. Table B.1.12)
<result5> - LR1 result, depending on the value of BufferP[2] (cf. Table B.1.12)
<result6> - LR2 result, depending on the value of BufferP[2] (cf. Table B.1.12)
VLM mode:
<result1> - Peak result, depending on the value of BufferP[2] (cf. Table B.1.13)
<result2> - P-P result, depending on the value of BufferP[2] (cf. Table B.1.13)
<result3> - Max result, depending on the value of BufferP[2] (cf. Table B.1.13)
<result4> - RMS result, depending on the value of BufferP[2] (cf. Table B.1.13)
(4) results of the measurement from the third profile if the corresponding LOGGER position was active
(BufferP [3] in Table B.1.12 or Table B.1.13); up to six words are written: