RUN NOW Excite +: Technical Service guide - rev. 6.2
Page 6.7
6.2.1.3. Inverter Test
The inverter test checks the condition of theAT UL driver. The test can have two outcomes:
“Test Successful, press Enter to continue”: This means that the test was completed
successfully and the inverter is not in an error condition.
“Inverter Error, press Enter to continue”: This means that the test was not completed
successfully, i.e. that the serial link is inactive and/or the inverter is in an error condition.
6.2.1.4. LED Test
The LED test checks the functioning of the display by lighting all the LEDs in the matrix. It also
tests the buzzer, varying the frequency to produce different tones of sound.
The test does not produce a result message, so the user must visually check the outcome.
6.2.1.5. Serial Ports Test
The serial ports test checks the following communication ports:
C-Safe COM test;
Low Kit COM test;
TGS COM test.
Using the + and speed keys, select the desired test item and confirm by pressing ENTER. The test
can have two outcomes:
“Test Successful, press Enter to continue”: This means that the test was completed
successfully, i.e. that serial communications on the selected port are correct.
“COMx Error, press Enter to continue”: This means that the outcome of the test was negative:
the message will specify COM1 in the case of the C-Safe COM test, COM2 in the case of
communications with the low kit, or COM3 in the case of the TGS COM test.
The “TGS COM test” done on machine not provided with the key reader gives a fail
outcome. The same if the “C-Safe COM test” is done on a machine which C-Safe port is
not plugged with the monitor plug described at paragraph: 4.3. Monitor plug for C-
Safe port”.
6.2.2. MANUAL TEST
The tests grouped under this section conduct checks on the machine’s operation in a fully automatic
manner. After selecting the desired test using the + and effort level keys, press ENTER to initiate
the test and then await the result. To exit test mode, press and hold down the CLEAR key for a few