RUN NOW Excite +: Technical Service guide - rev. 6.2
Page 6.44
6.17.2. HAND SENSOR
HUMAN BODY “CONTINUITY”: it’s well known that for somebody it’s very difficult,
nearly impossible, to measure their HR using the hand sensors. This due to a lot of
possible causes which could fake the “quality” of the contact between the human skin
and the HS plates, as: hands only just washed or particularly dry, acidity of the skin
and/or a particular body fat mass index. For these people it’s suggested to wear the chest
belt transmitter.
HS CORRECT USE: Grasp both the upper and lower plate avoiding clenching them too
hardly. Avoid washing the hands using soaps that can dry the skin too much.
NO
Receiver Board
defective.
Replace.
THE TELEMETRIC HR
SIGNAL IS INCORRECT
(Hand Sensor)
Set the priority on the
Hand Sensor.
Problem solved?
Check the state of
wear of Hand Sensor cable.
Problem solved?
OK
OK
NO
2
OK
NO
YES
Check the Display SW
versione and the grounding of
the Receiver Board.
3
YES
YES
1
NO