RUN NOW Excite +: Technical Service guide - rev. 6.2
Pagina 9.18
9.3.4. UPDOWN SETTINGS
This function allows access to the parameters in the UpDown table which define the number of
encoder pulses that correspond to different machine incline positions. To access this menu, when
the LED display shows:
UPDOWN SETTINGS
press ENTER. This function is structured as follows:
UPDOWN SETTINGS
+20%:
-5.0%:
WRITE TO
LOW KIT ?
DEFAULT
SETTINGS ?
READ FROM
LOW KIT ?
.......................
In addition to the 50 configuration parameters, this function also includes the 3 sub-functions
described below:
9.3.4.1. Read from low kit
To read the parameter values from the low kit memory to view them on the display, scroll using the
+/- keys until the LED display shows
READ FROM LOW KIT ?
press ENTER to read the parameters from the low kit, then return to the upper menu level by
pressing CLEAR for a few seconds.
9.3.4.2. Write to low kit
To write the values of the currently displayed parameters to the low kit, scroll using the +/- keys
until the LED display shows:
WRITE TO LOW KIT ?
press ENTER to write the parameters to the low kit, and return to the upper menu level by pressing
CLEAR for a few seconds.