RUN NOW Excite +: Technical Service guide - rev. 6.2
Page 7.22
7.6. DISASSEMBLING THE HS/HR CARDIO RECEIVER (CHEST
BELT / HAND SENSOR)
Figure 7-37
1. Release the emergency cable (a)
from its
housing.
2. Back off the 2 screws (b) using a medium
Phillips screwdriver.
3. Remove the inspection plug (c).
Figure 7-38
4. Remove the adhesive tape (or the cable tie)
(d) and the nylon bag (e).
Figure 7-39
5. Remove the sponge (f).
6. Unplug the connector and the fast-on,
highlighted in the figure.
To reassemble the HS/HR Receiver,
carry out the above steps in reverse order.
CAUTION:
During the reassembly:
place the coil (g), upwards oriented and
toward the user.
CAUTION: During the reassembly: fold
the sponge on the Board: carefully and
without pressing.