RUN NOW Excite +: Technical Service guide - rev. 6.2
Page 6.24
Code
Error
Description
Solution
08 8/EdA
SPEED Error: The Driver is
unabl
e to operate the belt at
the set speed.
Check that contacting is good on the ENCODER
cable, motor side;
After visual inspection, check the IPA35 and/or
IPA36 parameters by manually moving the belt
and at the same time performing “Read from Low
Kit”;
Check the state of the materials;
If points 1 and 2 are OK, replace the Driver and
the motor in sequence.
09 9/OtM
THERMAL PROTECTION
of tread belt MOTOR
interrupted.
Check the state of the treadmill;
Check the state of the treadmill deck;
Check the Tread Belt Motor;
If the materials are in a good state of repair and
Er09 occurs frequently, replace the motor;
(*).
10 10/Oli
DRIVER OVERLOAD, due
to a direct current that
exceeds the maximum
threshold permitted for the
inverter in the maximum
permitted time (I2t).
Check the state of the materials;
Check the usage conditions: a heavy user (> 100
Kg) at high speed (> 16 kmh) for several minutes
(>= 4) may generate the condition;
Check the state of the motor contacts on the
ENCODER side;
If the Encoder connector is OK
, the materials are
OK and the usage conditions far from the
extremes, replace the Driver;
(*).
11 11/OLm
MOTOR OVERLOAD, due
to a direct current that
exceeds the maximum
threshold permitted for the
motor in the maximum
permitted time (I2t).
Check the conditions of the equipment;
Check error 9.
12 12/OLr
BRAKING RESISTANCE
OVERLOAD.
Check resistance = 150Ω (this can be checked
only inside the Driver);
Check the Driver.
13
13/SMP
S
Defective power supply to
High Kit (HK).
If the error persists for some time, replace the
Driver.
14 14/PH
ENCODER TIMING Error:
This occurs when the Drive
r
reveals a reverse movement,
and may also arise after the
initial timing.
If the error persists for some time: check the
contacts on the motor side of the ENCODER
cable or replace the motor.
In case of the error does not resets, turn off for
a prolonged time the equipment
(approximately 10 min).

Table of Contents