C-56 Micro-Tech 9101/9201 Reference Manual, Rev J Thermo Fisher Scientific
The following tables show the read and write data.
Ethernet IP - Data Table
Configuration Parameters
Type
Parameter
Value
Remark
Reading data (Input)
Service
Type
Read Assembly
(CntrlLlogix - Compact Logix)
May be different
Service
Code
E (hex)
Class
4 (hex)
Attribute
3 (hex)
Instance
64 (hex) - 100 (dec)
Length Size
D2 (hex) - 210 (dec)
According data Table
Read Data Table
Register Name
Comments
Register Start
Number
OffSet
Success_Flag
Both
0
0
Status LED
BOTH
1
2
Status
Scale 1
2
4
Alarms
BOTH
6
12
I/O
BOTH
12
24
Number Of trials
BOTH
24
48
Model ID
BOTH
25
50
Batch Number
Scale 1
26
52
Batch Deviation
Scale 1
27
54
AZ Deviation
Scale 1
28
56
Zero Number
Scale 1
30
60
Zero Reference
Scale 1
32
64
Free Space
Scale 1
34
68
Free Space
Scale 1
35
70
Free Space
Scale 1
36
72
Free Space
Scale 1
37
74
Free Space
Scale 1
38
76
Free Space
Scale 1
39
78
Free Space
Scale 1
40
80
Free Space
Scale 1
41
82
Free Space
Scale 1
42
84
Free Space
Scale 1
43
86
Span Number
Scale 1
44
88
Scale Capacity
Scale 1
46
92
Speed Capacity
Scale 1
48
96
Load Cell Capacity
Scale 1
50
100
Read/Write