C-36 Micro-Tech 9101/9201 Reference Manual, Rev J Thermo Fisher Scientific
The table below provides more details about the Modbus registers.
Register Name Comments
Register Start
Number
OffSet
Success_Flag
Both
1
0
Display
Both
2
2
Status LED Both 82 162
Status Scale 1 83 164
Alarms
Both
87
172
I/O Both 93 184
Number Of trials Both 105 208
Command Scale 1 106 210
Last Key Pressed
Both
108
214
Model ID
Both
109
216
Batch Number Scale 1 110 218
Batch Deviation Scale 1 111 220
AZ Deviation
Scale 1
112
222
Zero Number
Scale 1
114
226
Zero Reference Scale 1 116 230
Free Space Scale 1 118 234
Free Space
Scale 1
119
236
Free Space Scale 1 120 238
Free Space Scale 1 121 240
Free Space Scale 1 122 242
Free Space
Scale 1
123
244
Free Space Scale 1 124 246
Free Space Scale 1 125 248
Free Space Scale 1 126 250
Free Space
Scale 1
127
252
Span Number
Scale 1
128
254
Scale Capacity Scale 1 130 258
Speed Capacity Scale 1 132 262
Load Cell Capacity
Scale 1
134
266
Rate Scale 1 136 270
Load Scale 1 138 274
Speed Scale 1 140 278
Master Total
Scale 1, Single Float Information
142
282
Reset Total
Scale 1, Single Float Information
144
286
Operator Total Scale 1, Single Float Information 146 290
Batch Total Scale 1, Single Float Information 148 294
Batch Setpoint
Scale 1
150
298
Batch Preset
Scale 1
152
302
Batch Preact Scale 1 154 306
AZT Correction Scale 1 156 310
Auto Zero Max Dev
Scale 1
158
314
Total AZ % Scale 1 160 318
AZT step limit Scale 1 162 322