Initializing the Micro-Tech
Acquiring Basic System Data
2-8 Micro-Tech 9101/9201 Reference Manual, Rev J Thermo Fisher Scientific
Figure 2–5. Pivot-to-Test-Weight Length
If the static-weight option is installed, measure the height from the pivot
to the carriage, and enter the result in Table 2–1 or Table 2–2. If this
option is not available, leave at the default value.
Figure 2–6. Pivot-to-Carriage Height
If the static-weight option is installed, measure the height from the carry
roller to the conveyor stringer, and enter the result in Table 2–1 or
Table 2–2. If this option is not available, leave at the default value.
Figure 2–7. Roller-to-Stringer Height
Determine the number of load cells, and enter the result in Table 2–1 or
Table 2–2.
Pivot-to-Carriage
Height
Roller-to-Stringer
Height
Number of Load Cells